Lucent Technologies R5SI User Manual

Page of 2643
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-1470
TIE-TRK (Tie Trunk) 
10
Tie Trunk EPF Test (#74)
This test consists of an E lead and M lead test. The E lead test checks for the 
proper activation and deactivation of the port’s E lead. The M lead test checks 
the M lead EPF current flow. The processor sends an M lead test request to the 
circuit pack and receives the results. The returned results are measured to see if 
a port or external tie trunk line fails.
0
NO 
BOARD
The test could not relate the internal ID to the port (no 
board).
1. Check to ensure that the board translations are 
correct. Translate the board, if necessary.
2. Issue the 
busyout board
 command.
3. Issue the 
reset board
 command.
4. Issue the 
release busy board
 command.
5. Issue the 
test board
 command. This should 
re-establish the linkage between the internal ID and 
the port.
Table 10-445.
Seizure Tests (#73, #747, #73)  — 
Continued
Error 
Code
Test 
Result
Description/ Recommendation
Continued on next page