Maintenance Object Repair Procedures
Page 10-1470
TIE-TRK (Tie Trunk)
10
Tie Trunk EPF Test (#74)
This test consists of an E lead and M lead test. The E lead test checks for the
proper activation and deactivation of the port’s E lead. The M lead test checks
the M lead EPF current flow. The processor sends an M lead test request to the
circuit pack and receives the results. The returned results are measured to see if
a port or external tie trunk line fails.
proper activation and deactivation of the port’s E lead. The M lead test checks
the M lead EPF current flow. The processor sends an M lead test request to the
circuit pack and receives the results. The returned results are measured to see if
a port or external tie trunk line fails.
0
NO
BOARD
BOARD
The test could not relate the internal ID to the port (no
board).
board).
1. Check to ensure that the board translations are
correct. Translate the board, if necessary.
2. Issue the
busyout board
command.
3. Issue the
reset board
command.
4. Issue the
release busy board
command.
5. Issue the
test board
command. This should
re-establish the linkage between the internal ID and
the port.
the port.
Table 10-445.
Seizure Tests (#73, #747, #73) —
Continued
Error
Code
Test
Result
Description/ Recommendation
Continued on next page