Lucent Technologies R5SI User Manual

Page of 2643
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-1621
UDS1-BD (UDS1 Interface Circuit Pack) 
10
One-Way Span Test (#1214)
This test is destructive.
The One-Way Span Test allows one-way span testing to and from remote test 
equipment or another DEFINITY communications system. This will test all 
circuitry and facilities from the local TN464F DS1 board to the remote test 
equipment or other DEFINITY communications system.
The test is destructive and can only be initiated by a system technician 
demanded 
test ds1-loop PCSS one-way-span-test-begin
 command.
 
PASS
The Far CSU Loopback test has successfully began 
executing. The test will continue to run until the system 
technician enters the 
test ds1-loop PCSS 
end-loopback/span-test
 command or the 
release board 
PCSS
 command.
0
NO 
BOARD
The test could not relate the internal ID to the port (no 
board). This could be due to incorrect translations, no 
board is inserted, an incorrect board is inserted, or an 
insane board is inserted.
1. Ensure that the board translations are correct. 
Execute the 
add ds1 PCSS
 command to administer 
the UDS1 interface if it is not already administered.
2. If the board was already administered correctly, 
check the error log to determine whether the board 
is hyperactive. If this is the case, the board is shut 
down. Reseating the board will re-initialize the 
board.
3. If the board was found to be correctly inserted in 
step 1, then issue the 
busyout board
 command.
4. Issue the 
reset board
 command.
5. Issue the 
release busy board
 command.
6. Issue the 
test board long
 command.
This should re-establish the linkage between the internal 
ID and the port.
Table 10-473.
TEST #1213 Far CSU Loopback Test  — 
Continued
Error 
Code
Test 
Result
Description/ Recommendation
Continued on next page