Lucent Technologies R5SI 用户手册
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-1621
UDS1-BD (UDS1 Interface Circuit Pack)
10
One-Way Span Test (#1214)
This test is destructive.
The One-Way Span Test allows one-way span testing to and from remote test
equipment or another DEFINITY communications system. This will test all
circuitry and facilities from the local TN464F DS1 board to the remote test
equipment or other DEFINITY communications system.
equipment or another DEFINITY communications system. This will test all
circuitry and facilities from the local TN464F DS1 board to the remote test
equipment or other DEFINITY communications system.
The test is destructive and can only be initiated by a system technician
demanded
demanded
test ds1-loop PCSS one-way-span-test-begin
command.
PASS
The Far CSU Loopback test has successfully began
executing. The test will continue to run until the system
technician enters the
executing. The test will continue to run until the system
technician enters the
test ds1-loop PCSS
end-loopback/span-test
command or the
release board
PCSS
command.
0
NO
BOARD
BOARD
The test could not relate the internal ID to the port (no
board). This could be due to incorrect translations, no
board is inserted, an incorrect board is inserted, or an
insane board is inserted.
board). This could be due to incorrect translations, no
board is inserted, an incorrect board is inserted, or an
insane board is inserted.
1. Ensure that the board translations are correct.
Execute the
add ds1 PCSS
command to administer
the UDS1 interface if it is not already administered.
2. If the board was already administered correctly,
check the error log to determine whether the board
is hyperactive. If this is the case, the board is shut
down. Reseating the board will re-initialize the
board.
is hyperactive. If this is the case, the board is shut
down. Reseating the board will re-initialize the
board.
3. If the board was found to be correctly inserted in
step 1, then issue the
busyout board
command.
4. Issue the
reset board
command.
5. Issue the
release busy board
command.
6. Issue the
test board long
command.
This should re-establish the linkage between the internal
ID and the port.
ID and the port.
Table 10-473.
TEST #1213 Far CSU Loopback Test —
Continued
Error
Code
Test
Result
Description/ Recommendation
Continued on next page