Maintenance Commands and Trouble-Clearing Aids 
Page 8-41
busyout tdm 
8
Permissions
The following default logins may execute this command: system technician, 
inads, init.
Examples
busyout tdm 1a
Description
The busyout tdm command will put the specified tdm bus in a maintenance busy 
state. There will be no periodic or scheduled tests performed on the busied out 
bus until it is released. When the object is maintenance busy then the object is 
removed from active service on the switch (i.e., no call processing activity may 
include the busied object). Warning alarms are generated (error type 18) on 
each tdm bus busied out, so that INADS can access the state of the objects. The 
release tdm command will return the specified tdm bus to operation.
Defaults
No defaults.
Parameters
Help Messages
If the system technician presses 
HELP
 after entering "busyout tdm," the following 
message will be displayed:
 Enter TDM bus location: [network(1-3)];carrier(A-B)
Error Messages
If the technician does not enter a port network number followed by bus, the 
following message will be displayed:
 Identifier invalid
pn number
The PN number specifies the Port Network number of the TDM bus to 
be busied out.
bus
The TDM bus ("a" or "b") specifies which half of the TDM bus is desired. 
Each 512 time slot TDM bus is configured as two duplicate 256 time 
slot buses. This division allows for duplication of control channels and 
dedicated tone time slots. The default control bus (carrying the control 
channel) is the "a" bus, while the default tone bus (carrying dedicated 
tones) is the "b" bus. A port-network number (1 - 3) may be entered with 
or without a leading zero (0).