Lucent Technologies R5SI User Manual

Page of 2643
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Commands and Trouble-Clearing Aids 
Page 8-44
busyout tone-clock 
8
Parameters
Help Messages
If the system technician presses 
HELP
 after entering "busyout tone-clock," the 
following message will be displayed:
 Enter tone/clock location: [cabinet(1-3];(carrier(A-E))
Error Messages
If an identifier greater than 3 (three) characters is entered, or the cabinet entered 
is not a digit (number), the following message will be displayed:
 Identifier invalid
If the carrier entered is invalid, the following message will be displayed:
 Invalid carrier specified
If the cabinet entered is not within the valid range of cabinets or the cabinet is not 
administered, the following message will be displayed:
 Cabinet number not assigned
If there is no tone/clock board at the specified location, one of the following 
messages will be displayed:
 Board not inserted
 Board not assigned
If the specified cabinet carrier location is that of a switch node, the following 
message will be displayed:
 Switch Node carrier specified; invalid command for SN carrier
If the cabinet carrier location entered is that of an EPN that is not available, the 
following message will be displayed:
 EPN is not available
If the tone/clock is active and the specified action is busyout, the following 
message will be displayed:
 Illegal Command for active object; use ’set’ to switch to standby
If the command entered is in conflict with another currently executing command, 
then a message will be displayed showing the login id of the conflicting user and 
the conflicting command. The message is as follows:
 ’login id’:’command’ has a command conflict
location
A "location" represents the physical position of the tone/clock to be 
busied out and is entered as "UUc" where "UU" represents the cabinet 
number, and "c" represents the carrier. A cabinet number (1 - 3) may 
be entered with or without a leading zero (0).