Lucent Technologies R5SI User Manual

Page of 2643
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Commands and Trouble-Clearing Aids 
Page 8-45
busyout trunk 
8
If during the execution of a command a resource problem occurs that requires 
the user to restart the command, then the following message will be displayed:
 Command resources busy; Press CANCEL to clear, and then resubmit
If all of the available maintenance resources are currently in use, then the 
following message will be displayed:
 All maintenance resources busy; try again later
Output
For the following output example, assume that the command that was entered is 
"busyout tone-clock 1a."
Feature Interactions
None.
busyout trunk
This command will busyout a specified trunk group or trunk group member.
Port
The tone clock maintenance object will only display the cabinet 
and carrier of the desired tone/clock board.
Maintenance Name
The type of tone clock circuit pack that is being busied out which 
is TONE-PT, TDM-CLK and TONE-BD.
Alt. name
Not applicable.
Result
The result of the busyout -"PASS," "ABORT," "FAIL".
Error Code
A system-generated number that tells why the busyout failed or 
aborted. A detailed list of the codes can be in the 
"Busyout/Release Error Codes" section of this chapter.
 
 busyout tone-clock 1a                            SPE A
                            COMMAND RESULTS
   Port    Maintenance Name  Alt. Name   Result       Error Code
   01A     TONE-PT                       PASS
   01A     TDM-CLK                       PASS
   01A     TONE-BD                       PASS