Lucent Technologies R5SI User Manual

Page of 2643
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Commands and Trouble-Clearing Aids 
Page 8-353
set signaling-group 
8
All of the fields on page 2 allow the same values. If the value in one of these fields 
is not numeric, the following message is displayed:
Entry must be all digits
All of the fields on pages page 2 allow the same values. If the value in one of 
these fields is a digit other than 1, 2, 3, or 4, the following message is displayed:
Entry out of range
Output
After the user has entered in the changes to the options and pressed SUBMIT, 
the following message appears at the bottom of the screen:
Command successfully completed
Feature Interactions
None.
set signaling-group
This command sets the secondary D-channel within the specified group to be the 
primary D-channel.
Synopsis
set signaling-group group identifier
Permissions
The following default logins may execute this command: system technician, 
inads, init.
Examples
set signaling-group 1
set signaling-group 2
Description
The set signaling-group command sets the secondary D-channel in the specified 
signaling group to be the primary D-channel. The primary D-channel then 
becomes the secondary D-channel.