Lucent Technologies R5SI User Manual

Page of 2643
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Commands and Trouble-Clearing Aids 
Page 8-354
set signaling-group 
8
A signaling group is a collection of B-channels signaled for by a designated 
single D-channel or set of D-channels over an ISDN-PRI.
Defaults
None.
Parameters
Help Messages
If the system technician presses 
HELP 
after entering "set signaling-group," the 
following is displayed:
Enter group identifier
Error Messages
If the specified group identifier is non numeric or out of range, the following 
message is displayed:
Signaling group invalid
If the specified group identifier is not administered, the following message is 
displayed:
No signaling group assigned
If during the execution of a command a resource problem occurs that requires 
the user to restart the command, then the following message is displayed:
Command resources busy; 
Press CANCEL to clear, and then resubmit
If all of the available maintenance resources are currently in use, then the 
following message is displayed:
All maintenance resources busy; try again later
Output
If the set signaling-group command is successful, the following message will be 
displayed on the SAT:
Command successfully completed
If the set signaling-group command is unsuccessful, the following message will 
be displayed:
group identifier
The signaling group identifier is an administered number associated 
with each signaling group.