Lucent Technologies R5SI User Manual

Page of 2643
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Commands and Trouble-Clearing Aids 
Page 8-650
test shadow-link 
8
Output
The responses will be displayed on a test-by-test basis with one line of data 
displayed for each test result.
For the following output example, assume that the command that was entered 
was "test processor a".
Feature Interactions
None.
test shadow-link
This command allows the technician to test the shadow link.
Port
The port address (cabinet-carrier) of the maintenance object that 
is being tested.
Maintenance Name
The type of maintenance object that is being tested is MEMORY.
Alt. Name
Not applicable.
Test No.
The actual test that is being executed.
Result
The result of the individual test -"PASS," "ABORT," "FAIL," "NO 
BOARD," "DISABLED," "EXTRA BD".
Error Code
A system-generated number that tells why the release failed or 
aborted. A detailed list of the codes according to "Test No." is 
provided for each MO.
 
 test processor a                               SPE B
                           TEST RESULTS
   Port    Maintenance Name  Alt. Name Test No. Result      Error Code
   01A     PROCR                        77      PASS
   01A     PROCR                        80      PASS
   01A     PROCR                        82      PASS
   01A     PR-MAINT                    102      ABORT       1018
   01A     PR-MAINT                    103      ABORT       1018
   01A     PR-MAINT                    106      PASS
   01A     PR-MAINT                    228      PASS
   01A     PR-MAINT                    229      ABORT       1018
   01A     MEMORY                       87      PASS
   01A     MEMORY                      631      PASS
 Command successfully completed