Lucent Technologies R5SI User Manual

Page of 2643
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Commands and Trouble-Clearing Aids 
Page 8-652
test shadow-link 
8
Help Messages
If the system technician presses 
HELP
 after entering "test shadow-link" the 
following message will be displayed:
Enter [’long’ or ’short’],
[’repeat’ (1-100) or ’clear’], [’schedule’]
Error Messages
If the command entered is in conflict with another currently executing command, 
then a message will be displayed showing the login id of the conflicting user and 
the conflicting command. The message is as follows:
’login id’:’command’ has a command conflict
If the standby is entering maintenance mode when this command is executed, 
then the following message is displayed:
Cannot interrupt Standby SPE while entering 
maintenance mode; please try later
If the standby SPE is not refreshed when this command is executed, then the 
following message is displayed:
Standby SPE memory not refreshed; 
use the "refresh spe-standby" command.
If the standby SPE is not refreshed and the active SPE is hard selected via the 
SPE select switches when this command is executed, then the following 
message is displayed:
Active SPE locked via select switches;
Standby SPE memory not refreshed
repeat number
The "number" specifies how many times each test in the sequence is 
to be repeated. "Number" may be any integer between 1 and 100.
clear
This option causes the test sequence (short or long) to repeat until the 
alarm (if one exists against the maintenance object) is cleared or a 
single test in the sequence fails. If no alarms are registered against the 
maintenance object then the test sequence will be exercised only 
once. The long clear option forces a clear of all alarms if no errors are 
encountered during testing. The short clear option only clears alarms 
pertinent to tests in the short sequence.
schedule
When the "schedule" option is specified, the command is validated 
and then a scheduling form is displayed to allow the technician to 
schedule execution of the command. The command is then placed in 
the command queue and is executed at the specified time. The 
information displayed by the command is sent to the system printer 
instead of the screen. Refer to the Report Scheduler and System 
Printer feature specification [1] for more details.