Lucent Technologies R5SI User Manual

Page of 2643
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Commands and Trouble-Clearing Aids 
Page 8-663
test station 
8
Feature Interactions
The testing of the standby SPE maintenance object makes the standby SPE 
unavailable to take over for the active SPE.
test station
This command performs hardware diagnostic tests on an individual port circuit 
that is associated with the extension.
Synopsis
test station extension 
[ short | long ][ repeat number | clear ] schedule
Permissions
The following default logins may execute this command: system technician, 
inads, cust, init, nms.
Examples
test station 81709 l 
test station 85136 s r 2
test station 85036 l r 25
test station 85036 l r 25 schedule
test station 84297 r 4
test station 81709 c
 
 test spe-standby                               SPE A
                             TEST RESULTS
 
 Port    Maintenance Name Alt. Name Test No. Result       Error Code
 01B     SHDW-CIR                   285                   PASS
 01B     SHDW-CIR                   284                   PASS
 01B     SPE-SELECT                 278                   PASS
 01B     DUPINT                     315                   PASS
  .        .                         .                      .
  .        .                         .                      .
  .        .                         .                      .
 Command Successfully Completed