DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Commands and Trouble-Clearing Aids 
Page 8-662
test spe-standby 
8
If the standby SPE is not refreshed and the active SPE is hard selected via the 
SPE select switches when this command is executed, then the following 
message is displayed:
Active SPE locked via select switches; 
Standby SPE memory not refreshed
If the standby SPE is busy with another task, then the following message is 
displayed:
Standby SPE busy with another task; 
for information use "status system 1"
If the standby SPE is not available when this command is executed, then the 
following message is displayed:
Standby SPE not available; 
for information use "status system 1"
Output
The responses will be displayed on a test-by-test basis with one line of data 
displayed for each test result.
For the following output example, assume that the standby SPE is located in 
carrier B and the command entered is "test spe-standby".
Port
The port address (cabinet-carrier-slot-circuit) of the maintenance 
object that is being tested. This maintenance object will display 
the cabinet and carrier location of the standby SPE only.
Maintenance Name
The type of maintenance object that is being tested.
Alt. Name
The alternate means of identifying the maintenance object. This 
field contains the extension when the object is a data module.
Test No
The actual test that is being executed.
Result
The result of the individual test -"PASS," "ABORT," "FAIL," "NO 
BOARD," "DISABLED,".
Error Code
A system-generated number that tells why the test failed or 
aborted. A detailed list of the codes according to "Test No." is 
provided for each MO.