Lucent Technologies R5SI User Manual

Page of 2643
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Commands and Trouble-Clearing Aids 
Page 8-687
upgrade software 
8
If the SPE-select switches are thrown to prevent the SPE-interchange during a 
software upgrade, the following message is displayed:
SPE select switches thrown; upgrade complete only on standby
If the standby SPE is not in the standby mode and is busy running tests, the 
following message will be displayed:
Standby SPE busy with another task; 
for information use ’status system’
If the standby SPE has not completed initialization, the following message will be 
displayed:
Standby SPE memory not refreshed; Use ’refresh spe-standby’
If the active SPE cannot communicate with the standby SPE after the standby 
SPE is properly upgraded, the following message will be displayed:
Upgrade failed; no communication with 
standby after new software booted
If the SPE-interchange failed and the new software cannot be run in the active 
SPE, the following message is displayed:
Software upgrade failed, could not perform an interchange
Output
The following is the output of a successful simplex upgrade upon entering the 
"upgrade software" command:
 
 INITIATING SOFTWARE UPGRADE
 MEM-CARD CHECKSUMPASSED
REPROGRAMMING MTPPASSED
ERASING MEMORYPASSED
REPROGRAMMING SPEPASSED
FLASH TEXT CHECKSUM       PASSED
 UPGRADE COMPLETE
 <beep>
 REPLACE SOFTWARE MEM-CARD WITH TRANSLATION MEM-CARD
 <beep>