DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Commands and Trouble-Clearing Aids 
Page 8-688
upgrade software 
8
Explanations and error recoveries to the above steps are as follows:
Feature Interactions
System Restarts
An upgrade will cause a system restart. Simplex systems will result in a level-4 
restart. Duplex system will undergo a level-2 SPE-interchange after the standby 
is upgraded through a level-4 restart.
INITIATING SOFTWARE 
UPGRADE: 
This indicates that the system is proceeding to do a 
software upgrade.
MEM-CARD CHECKSUM: 
If the card-mem checksum fails, the system will reboot 
without performing an upgrade. Retry the command with 
another software card-mem.
REPROGRAMMING MTP: 
If the MTP programming fails, the Manager I will not be 
functional anymore. So the rest of the upgrade (if it occurs) 
will not be visible. Nor will the MTP be present to monitor 
the health of the processor. The only recovery procedure 
is to power down and power up the system since the 
presence of a software card-mem will cause a software 
upgrade.
ERASING MEMORY: 
The rest of the memory is being erased.
REPROGRAMMING SPE: 
This shows the status of the reprogramming. A total of 7 
Mbytes has to be reprogrammed. If the reprogramming 
fails in the midst of upgrade, it will take the system into 
SPE-down
 mode. In this mode, the system technician can 
only reset the system or display alarms. The system 
should be reset, and another upgrade attempt will be 
done due to the detection of a software card-mem in the 
system.
FLASH TEXT CHECKSUM: 
If the checksum fails, the software may or may not be 
healthy. But it will try to run for as long as it can until further 
system reset due to system technician intervention.
REPLACE SOFTWARE 
MEM-CARD WITH 
TRANSLATION 
MEM-CARD: 
The system technician is prompted by a beep and this text 
string on the Manager I to replace the software card-mem 
with the translation card-mem. The system boots without 
translation if the replacement is not done within 2 minutes. 
The only way to recover from this is to replace the 
card-mem and issue a 
reset system 3
 to read in the 
translations again.
UPGRADE COMPLETE: 
This indicates that the software upgrade is completed.