Lucent Technologies R5SI User Manual

Page of 2643
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Packet Bus Fault Isolation and Correction 
Page 9-32
Packet Bus Fault Correction 
9
network. Use the TN771 Standalone mode to determine if the Packet Bus 
fault is resolved.
!
CAUTION:
Circuit packs in carriers that are not part of the shortened bus are not 
inserted. As a result, these circuit packs are not alarmed. Ignore these 
alarms for now. All alarms should be resolved when the cabinet is restored 
to its original configuration.
Figure 9-7.
Carrier Rewiring Example
Procedure 4 is organized into two parts, as follows:
Part 1:
1. Power down the PN. See 
 section in 
2. Replace all of the TDM/LAN cables and both TDM/LAN terminators.
3. Restore power to the PN. Se
 section in 
4. Determine if the packet bus fault is still present.
5. If the fault is present, go to Part 2.