Lucent Technologies R5SI 用户手册
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Packet Bus Fault Isolation and Correction
Page 9-32
Packet Bus Fault Correction
9
network. Use the TN771 Standalone mode to determine if the Packet Bus
fault is resolved.
fault is resolved.
!
CAUTION:
Circuit packs in carriers that are not part of the shortened bus are not
inserted. As a result, these circuit packs are not alarmed. Ignore these
alarms for now. All alarms should be resolved when the cabinet is restored
to its original configuration.
inserted. As a result, these circuit packs are not alarmed. Ignore these
alarms for now. All alarms should be resolved when the cabinet is restored
to its original configuration.
Figure 9-7.
Carrier Rewiring Example
Procedure 4 is organized into two parts, as follows:
Part 1:
1. Power down the PN. See
section in
2. Replace all of the TDM/LAN cables and both TDM/LAN terminators.
3. Restore power to the PN. See
section in
4. Determine if the packet bus fault is still present.
5. If the fault is present, go to Part 2.