DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-42
ADX16A-PT (AUDIX Analog Line/Control Link) 
10
Note:
a. Retry the command at 1-minute intervals a maximum of 5 times.
Loop Around Test (#161)
This test is designed to check the on-board transmission capabilities of the NPE 
on the analog port. 
Any
FAIL
The NPE of the tested port did not conference the tones correctly. This causes 
noisy and unreliable connections.
1. Replace the circuit pack.
PASS
The port can correctly conference multiple connections. User-reported 
troubles on this port should be investigated by using other port tests and by 
examining station, trunk, or external wiring.
Table 10-18.
TEST #161 Loop Around Test 
Error 
Code
Test 
Result
Description/ Recommendation
ABORT
Could not allocate the necessary system resources for this test. Try (a).
1000
ABORT
System resources required to run this test are not available. The port may be 
busy with a valid call. Use the 
display port PCSSpp
 command to determine 
the station extension. Use the 
status station
 command to determine the 
service state of the port. If the port is in use, wait until it is idle before testing.
1. If the port status is idle, try (a).
1002
ABORT
The system could not allocate time slots for the test. The system may be under 
heavy traffic conditions or it may have time slots out-of-service due to 
TDM-BUS errors. Refer to “TDM-BUS” to diagnose TDM-BUS errors.
1. If system has no TDM-BUS errors and is not handling heavy traffic, try (a).
Continued on next page
Table 10-17.
TEST #7 Conference Circuit Test  — 
Continued
Error 
Code
Test 
Result
Description/Recommendation
Continued on next page