Plasmon FS3102 User Manual

Page of 35
Raidtec FS3102 Hardware Installation Guide                          Version 1.0 
24 
 
Appendix A - Alerts 
 
Failure Events 
 
The following table summarizes the operation of the system in the presence of various failures. 
 
Email refers to an email notification sent by the controller over the Ethernet interface to an assigned email address, 
SNMP refers to an SNMP trap sent by the controller over the Ethernet interface to a designated SNMP recipient 
and Event log refers to an event logged in the Alert Log in the Raidtec Manager Management Software.  
 
FAILURE 
CLASS 
FAILURE 
TYPE 
EFFECT ON 
DATA 
EFFECT ON 
AVAILABILITY 
EFFECT ON 
PERFORMANCE 
USER 
NOTIFICATION 
Power 
(BBU Not 
present) 
Total Loss 
Data may be 
lost if write 
cache is 
enabled 
System unavailable 
N/A 
Event log  
Power 
(BBU Not 
present) 
Transient 
Loss 
Data may be 
lost if write 
cache is 
enabled 
System unavailable 
during power loss. 
Controller takes 7 
seconds to reboot and 
60 seconds for the 
system to become 
available. 
N/A 
Event log 
Power 
(BBU Present) 
Total Loss 
No effect 
provided 
outage is 
shorter than 
BBU hold time 
System unavailable 
N/A 
Event log 
Power 
(BBU Present) 
Transient 
Loss 
No effect 
System unavailable 
during power loss. 
Controller takes 7 
seconds to reboot and 
60 seconds for the 
system to become 
available. 
N/A 
Event log 
Disk 
(RAID Level 1, 
5 or 10) 
Drive 
removed or 
drive failure 
No effect. 
RAID volume 
degraded. 
 
Loss of high 
availability. System 
will become 
unavailable on 
second failure. 
Performance may 
drop 
Event log, Email 
and SNMP 
Disk 
(RAID Level 0) 
Drive 
removed or 
drive failure 
RAID is 
inaccessible 
RAID unavailable 
N/A 
Event log, Email 
and SNMP 
Disk 
(RAID Level 1, 
5 or 10) 
Advanced 
drive failure 
notice 
No effect 
 
No effect 
Performance will 
drop if spare is 
available to rebuild 
the failing drive to 
Event log, Email 
and SNMP  
Disk 
(RAID Level 0) 
Advanced 
drive failure 
notice 
No effect 
No effect 
None 
Event log, Email 
and SNMP 
Disk 
(RAID Level 1, 
5 or 10) 
Medium 
Error 
No effect  
Stripe will be rebuilt 
on alternate sectors. 
Performance may 
drop 
Disk statistics 
updated in 
controller 
If threshold met, 
Event log, Email 
and SNMP