Plasmon FS3102 User Manual

Page of 35
Raidtec FS3102 Hardware Installation Guide                          Version 1.0 
26 
 
Alert Messages 
 
The following Notifications and Warnings are sent by the controller. 
 
Notifications 
 
Normal operation of power supply in slot <number> restored 
Normal operation of fan in slot <number> restored 
The temperature in the system is now within the acceptable range 
Creating RAID ‘<name>’, useable capacity: <capacity> GB  
RAID ‘<name>’ is now accessible 
Initialising RAID ‘<name>’ 
Initialisation of RAID ‘<name>’ deferred for a higher priority RAID 
RAID ‘<name>’ initialisation complete 
Deleting RAID ‘<name>’ 
Expanding RAID ‘<name>’ by adding rows 
Expanding RAID ‘<name>’ by adding <number of columns> column(s)  
Initialising expansion space on RAID ‘<name>’ 
RAID ‘<name>’ expand complete 
Rebuilding RAID ‘<name>’ 
Rebuild of RAID ‘<name>’ deferred for a higher priority RAID 
RAID ‘<name>’ rebuild complete 
Disk in bay <number> is no longer part of RAID ‘<name>’ 
Verifying RAID ‘<name>’ 
Verification of RAID ‘<name>’ deferred for a higher priority RAID 
RAID ‘<name>’ verification complete 
Logical volume '<name>' created 
Logical volume '<name>' deleted 
Logical volume '<name>' capacity expanded to <capacity> 
Logical volume '<name>' ID:LUN changed to <SCSI ID>:<LUN> 
Logical volume '<name>' changed to '<new name>' 
Starting Firmware <version> (<build time and date>) reboot <reboot count> 
Network up at IP address <IP address>, netmask <netmask> 
Password has changed 
Fibre Channel Port <port> is up at <speed> Gb in <fibre channel mode> mode 
 
Warnings 
 
Disk in bay <number> is missing 
Disk in bay <number> has excessive errors 
Disk in bay <number> is running out of reallocation blocks 
Disk in bay <number> has run out of reallocation blocks 
Disk in bay <number> has failed 
Power Supply Module in slot <number> is not working properly 
Fan in slot <number> is not working properly 
The temperature in the system has exceeded <threshold value> threshold 
The temperature in the system has dropped below 10C/50F 
RAID ‘<name>’ initialisation failed to complete 
RAID ‘<name>’ verify failed to complete 
RAID ‘<name>’ expand failed to complete 
RAID ‘<name>’ rebuild failed to complete 
RAID ‘<name>’ is degraded due to disk failures 
RAID ‘<name>’ is inaccessible due to disk failures  
RAID ‘<name>’ has no suitable spare available 
Cannot start scheduled verify on RAID ‘<name>’ 
Controller hardware error 
Firmware download checksum failed, the binary may be corrupted 
Firmware ID does not match, the binary is not for this product