Reload Values and Errors for Each Internal Clock (Peripheral Clock (PCLK)) 
and Baud Rate
 
Table 5-3 Reload Values and Errors for Each Internal Clock (Peripheral Clock (PCLK)) and 
Baud Rate 
Baud rate 
(bps) 
8 MHz 
10 MHz 
16 MHz 
20 MHz 
24 MHz 
32 MHz 
Value  ERR  Value  ERR  Value  ERR  Value  ERR  Value  ERR  Value  ERR 
4M 
2.5M 
2M 
11 
15 
1M 
15 
19 
23 
31 
500000 
15 
19 
31 
39 
47 
63 
460800 
51 
-0.16 
250000 
31 
39 
63 
79 
95 
127 
230400 
103  -0.16 
153600 
51 
-0.16 
64 
-0.16  103  -0.16  129  -0.16  155  -0.16 
207 
-0.16 
125000 
63 
79 
127 
159 
191 
255 
115200 
68 
-0.64 
86 
0.22 
138 
0.88 
173 
0.22 
207  -0.16 
277 
0.08 
76800 
103  -0.16  129  -0.16  207  -0.16  259  -0.16  311  -0.16 
416 
0.08 
57600 
138 
0.08 
173 
0.22 
277 
0.08 
346  -0.16  416 
0.08 
555 
0.08 
38400 
207  -0.16  259  -0.16  416 
0.08 
520 
0.03 
624 
832 
-0.04 
28800 
277 
0.08 
346  <0.01  554  -0.01  693  -0.06  832  -0.03  1110  -0.01 
19200 
416 
0.08 
520 
0.03 
832  -0.03  1041  0.03  1249 
1666 
0.02 
10417 
767  <0.01  959  <0.01  1535  <0.01  1919  <0.01  2303  <0.01  3071  <0.01 
9600 
832 
0.04  1041  0.03  1666  0.02  2083  0.03  2499 
3332  -0.01 
7200 
1110  <0.01  1388  <0.01  2221  <0.01  2777  <0.01  3332  <0.01  4443  -0.01 
4800 
1666  0.02  2082  -0.02  3332  <0.01  4166  <0.01  4999 
6666  <0.01 
2400 
3332  <0.01  4166  <0.01  6666  <0.01  8332  <0.01  9999 
13332  <-0.01 
1200 
6666  <0.01  8334  0.02  13332  <0.01  16666  <0.01  19999 
26666  <0.01 
600 
13332  <0.01  16666  <0.01  26666  <0.01 
300 
26666  26666  <0.01 
 
  Value: Setting value of the BGR register (decimal) 