Fujitsu FR81S User Manual

Page of 2342
CHAPTER 40: MULTI-FUNCTION SERIAL INTERFACE 
 
 
8. Operation of I2C 
 
FUJITSU SEMICONDUCTOR LIMITED 
CHAPTER : MULTI-FUNCTION SERIAL INTERFACE 
FUJITSU SEMICONDUCTOR CONFIDENTIAL 
331 
 
 Reload Values Relating to Baud Rates and Internal Clock Frequencies 
 
Table 8-2 Reload Values Relating to Baud Rates and Internal Clock Frequencies 
Baud rate 
[bps] 
Internal clock (peripheral clock (PCLK)) 
8MHz 
10MHz 
16MHz 
20MHz 
24MHz 
32MHz 
400000 
19 
24 
39 
49 
59 
79 
200000 
39 
49 
79 
99 
119 
159 
100000 
79 
99 
159 
199 
239 
319 
 
These numerical values apply when SCL rising of the I
2
C bus is 0s. When SCL rising of the I
2
C bus is slow, 
the baud rate becomes lower than the above numerical values. 
 
 Reload Counter Functions 
The reload counter consists of a 15-bit register for reload values and generates a transmission/reception 
clock from the internal clock. In addition, the count value of the transmission reload counter can be read via 
the baud rate generator register (BGR). 
 
 Count Start 
When a reload value is written to the baud rate generator register (BGR), the reload counter will start 
counting. 
 
 
MB91520 Series
MN705-00010-1v0-E
1644