Fujitsu FR81S User Manual

Page of 2342
CHAPTER 44: 12-BIT A/D CONVERTER 
 
 
4. Registers 
 
FUJITSU SEMICONDUCTOR LIMITED 
CHAPTER
 : 12-BIT A/D CONVERTER 
FUJITSU SEMICONDUCTOR CONFIDENTIAL 
47 
4.2.11. 
Range Compare Flag Register : ADRCIF0, 
ADRCIF1 
The bit configuration of the range compare flag register is shown. 
The range compare flag register (ADRCIF) indicates the interrupt factor by the continuous detection of the 
range comparison result. 
  ADRCIF0: Address 1440
H
 (Access: Byte, Half-word, Word) 
 
bit31 
bit30 
bit29 
bit28 
bit27 
bit26 
bit25 
bit24 
 
 
RCINT31  RCINT30  RCINT29  RCINT28  RCINT27  RCINT26  RCINT25  RCINT24 
Initial value 
Attribute 
R,WX 
R,WX 
R,WX 
R,WX 
R,WX 
R,WX 
R,WX 
R,WX 
 
 
 
 
 
 
 
 
 
 
bit23 
bit22 
bit21 
bit20 
bit19 
bit18 
bit17 
bit16 
 
 
RCINT23  RCINT22  RCINT21  RCINT20  RCINT19  RCINT18  RCINT17  RCINT16 
Initial value 
Attribute 
R,WX 
R,WX 
R,WX 
R,WX 
R,WX 
R,WX 
R,WX 
R,WX 
 
 
 
 
 
 
 
 
 
 
bit15 
bit14 
bit13 
bit12 
bit11 
bit10 
bit9 
bit8 
 
 
RCINT15  RCINT14  RCINT13  RCINT12  RCINT11  RCINT10 
RCINT9 
RCINT8 
Initial value 
Attribute 
R,WX 
R,WX 
R,WX 
R,WX 
R,WX 
R,WX 
R,WX 
R,WX 
 
 
 
 
 
 
 
 
 
 
bit7 
bit6 
bit5 
bit4 
bit3 
bit2 
bit1 
bit0 
 
 
RCINT7 
RCINT6 
RCINT5 
RCINT4 
RCINT3 
RCINT2 
RCINT1 
RCINT0 
Initial value 
Attribute 
R,WX 
R,WX 
R,WX 
R,WX 
R,WX 
R,WX 
R,WX 
R,WX 
[bit31 to bit0] RCINT31 to RCINT 0 : Conversion data error flag bits 
RCINT[n] 
Explanation 
Read 
Write 
Range comparison interrupt factor clear state 
Bit clear 
State of interrupt factor generation by continuous 
detection of range comparison result 
There is no change, and is no 
influence on another. 
 
(n=0 to 31) 
 
RCINT bit is set in "1" by the continuous detection of the range comparison result of the corresponding 
activation channel. 
 
When RCINT bit and the range comparison interrupt request enable of the corresponding activation 
channel are "1", the range comparison interrupt request is generated. 
 
MB91520 Series
MN705-00010-1v0-E
1850