Symmetricom 1100 User Manual

Page of 224
Chapter 4 Provisioning the TimeProvider
Provisioning Alarms
128  TimeProvider User’s Guide
097-58001-02 Revision G – April 2008
CLKWARM
Local oscillator on the 
specified IOC is in 
Warm-up mode
MN | MJ
IMMED
No
MN
MN
CLKFREE
Local oscillator on 
specified IOC is in 
Free-run mode
MN | MJ | 
CR
IMMED
No
MJ
MJ
CLKBRDG
Local oscillator on 
specified IOC is in 
Bridging mode
MN | MJ | 
CR
IMMED
No
MJ
MJ
CLKHOLD
Local oscillator on 
specified IOC is in 
Holdover mode
MN | MJ | 
CR
IMMED
No
MJ
MJ
<aid> = PRS
INPDISQ
Specified input has 
been disqualified or 
qualified as a possible 
system reference.
MN | MJ | 
CR
FLT 
DELAY
Yes
MN
MN
INPLOS
Specified input has 
Loss Of Signal.
1
MN | MJ | 
CR
IMMED
No
MN
MN
INPFRQ
Specified input has 
calculated received 
frequency that exceeds 
the pull-in range of the 
LO.This alarm condition 
disqualifies the input as 
a possible reference.
2
NR | NA | 
MN | MJ | 
CR
IMMED
No
MN
NR
INPPHASE
Specified input port’s 
phase measurement 
exceeds usable value.
NR | NA | 
MN | MJ | 
CR
IMMED
No
MN
MN
EXDSC
Input has had excessive 
discontinuities, indicated 
by more than 3 signal 
faults (OOF, BPV, CRC, 
or AIS) within a 5-minute 
window. The alarm 
clears when the 
5-minute window 
contains less than 3 
signal faults.
NR | NA | 
MN | MJ | 
CR
IMMED
No
MN
MN
Table 4-3.  Alarm Conditions and Defaults (Continued)
Alarm ID
Description of Alarm 
Condition
Possible 
Alarm 
Levels
Error 
Delay 
Default
Error 
Delay 
Editable?
Default Level
SSU 
Mode
SUB 
Mode