HGST TRAVELSTAR 80GN 30GB ATA5 08K0910 User Manual

Product codes
08K0910
Page of 214
Travelstar 80GN Hard Disk Drive Specification
152
 
13.32  Sense Condition (F0h: vendor specific)
Table 106: Sense Condition (F0h: vendor specific)
The Sense Condition command is used to sense temperature in a device. This command is executable without spin-
ning up even if a device is started with No Spin Up option. If this command is issued at the temperature out of 
range which is specified for operating condition, the error might be returned with IDN bit 1. 
Output parameters to the device
Feature
The Feature register must be set to 01h. All other values are rejected with setting ABORT 
bit in status register.
Input parameters from the device
Sector Count
The Sector Count register contains result value.
Value
Description
00h 
Temperature is equal to or lower than –20°C
01h–FEh
Temperature is (Value/2–20)°C
FFh 
Temperature is higher than 107°C
N
Not recommendable condition for start up. If over stressed condition is detected, this bit 
will be set to one.
Command Block Output Registers
Command Block Input Registers
Register
7 6 5 4 3 2 1 0
Register
7 6 5 4 3 2 1 0
Data
- - - - - - - -
Data
- - - - - - - -
Feature
0 0 0 0 0 0 0 1
Error
see below
Sector Count
- - - - - - - -
Sector Count
V V V V V V V V
LBA Low
- - - - - - - -
LBA Low
- - - - - - - N
LBA Mid
- - - - - - - -
LBA Mid
- - - - - - - -
LBA High
- - - - - - - -
LBA High
- - - - - - - -
Device
1 - 1 D - - - - 
Device
- - - D - - - - 
Command
1 1 1 1 0 0 0 0
Status
see below
Error Register
Status Register
7
6
5
4
3
2
1
0
7
6
5
4
3
2
1
0
CRC
UNC
0
IDN
0
ABT
T0N
AMN
BSY RDY
DF
DSC
DRQ
COR IDX
ERR
0
0
0
V
0
V
0
0
V
V
V
-
V
-
-
V