SEAL 44Ultra Laminator User Manual

Page of 49
 
 
Adjustment Procedures 
29 
 
5-2 Roller 
Nip 
 
Note: to perform the following adjustments, it is necessary to remove both plastic side covers first. 
See section 4-1: Disassembly / Reassembly Plastic Side Covers. 
 
Necessary tools: Allen Key 4mm, a set of metric thickness gauges. 
Approximate time: 5 minutes 
 
Note: the top roller must be at room temperature, before this procedure is being performed. 
 
1.  Set the roller opening to its minimum position by pushing and turning the nip setting knob fully 
counter-clockwise. (nip 0mm) 
2.  Loosen the bolts that hold the adjustment strip in such a way, that the strip can be moved up- and 
downward, but does not slide downward by its own weight. 
3.  Place a 0.6mm (0.0236 inch) gauge between the bearing housing and the adjustment strip. See 
figure 30: the white arrow points to the 0.6mm wide opening, caused by the gauge. 
4.  Push the adjustment strip upward against the gauge (figure 30) and fasten the M5 bolts while 
leaving the gauge in place. See figure 31. 
5.  When done, remove the gauge. 
6.  Perform steps 2 thru 5 at either side of the machine. 
 
 
fig. 31 
fig. 30 
push strip 
upward