ATTO Technology V-Class User Manual

Page of 117
89
 
ATTO Technology Inc. Diamond Storage Array Installation and Operation Manual
 9.2  Optional Hot Spare Sled
To maintain array up time with minimal risk of data loss, individual sleds which fail may be replaced 
with a spare sled in some configurations. 
In most configurations, if a member of a virtual 
device becomes degraded, you must swap out the 
faulted sled as defined in 
. If you have not enabled 
AutoRebuild, you must also start a manual 
rebuild.
For four configurations, however, Hot Spare sleds 
may be designated as replacements for faulted 
sleds without intervention by you or a host. 
Each configuration requires a certain number of 
Hot Spare sleds. These sleds, once designated as 
Hot Spares, are not available for other use.
The following configurations support optional 
Hot Spare sleds:
RAID Level 1:  
2 Hot Spare sleds
RAID Level 10:  
1 group, 2 Hot Spare sleds 
RAID Level 5:  
1 group, 1 Hot Spare sled 
RAID Level 5:  
2 groups, 2 Hot Spare sleds 
If a sled becomes degraded and a Hot Spare sled 
has been designated:
•  the Diamond replaces the degraded sled with 
the Hot Spare sled, simulating a hot swap of a 
sled with AutoRebuild enabled, without 
intervention 
•  any sled with a Faulted drive is not used. Faulted 
sleds maintain their faulted status until they are 
removed and re-inserted or if the system is 
restarted.
•  Hot Spares are handled as sleds, not as 
individual drives
•  the Hot Spare sled replaces the Faulted sled in 
the Virtual Device
•  a rebuild automatically starts after the hot spare 
is switched into the Virtual Device, even if 
AutoRebuild is disabled.
• the DriveInfo command lists the number of Hot 
Spare sleds currently in the system
•  you can replace the faulted drive or sled later. 
However, faulted is a non-persistent state. After 
a power cycle, the faulted sled displays on the 
DriveInfo
 screen as having no type, i.e, the 
type 
field is blank. The sled cannot be accessed but 
must be removed and replaced. If it is replaced, 
it becomes part of any open Virtual Disk in this 
order:
1. if a Virtual Device is missing a sled or you are hot 
swapping a sled, the new sled becomes part of the 
existing Virtual Device.
2 if a Hot Spare sled is missing, the new sled 
becomes a Hot Spare sled.
To set up RAID Level 1 with Hot Spare sleds
1
Connect to Diamond Storage Array services 
(refer to 
Accessing the Array 
on page 17) and use 
the CLI or enter ATTO ExpressNAV 
Advanced 
CLI Configuration page (refer to 
ATTO 
ExpressNAV: Browser-based Interface 
on page 25). 
2
Type 
set QuickRAID1 2
3
Type 
SaveConfiguration Restart
The Diamond is configured into one RAID Level 
1 group with two Hot Spare sleds.
To set up RAID Level 10 with Hot Spare sleds
1
Connect to Diamond Storage Array services 
(refer to 
Accessing the Array 
on page 17) and use 
the CLI or enter ATTO ExpressNAV browser 
interface 
Advanced
 CLI Configuration page. 
2
Type 
set QuickRAID10 1 2
3
Type 
SaveConfiguration Restart
The Diamond is configured into one RAID Level 
10 group with two Hot Spare sleds.
To set up one RAID Level 5 group with one Hot 
Spare sled
1
Connect to Diamond Storage Array services 
(refer to 
Accessing the Array 
on page 17) and use 
the CLI or enter ATTO ExpressNAV browser 
interface 
Advanced
 CLI Configuration page. 
2
Type 
set QuickRAID5 1 1 
3
Type 
SaveConfiguration Restart
The Diamond is configured into one RAID Level 