Connecting devices
Step 6: Install the Coupled Bonding Conductor
Installation of the G350 Media Gateway
51
December 2003
Connecting an external router to the G350
You can connect a router to any of the following ports on the G350:
the ETH WAN port on the G350 front panel. 
the ETH LAN port on the G350 front panel. 
the Gigabit Ethernet port on an MM314 media module.
one of the 24 10/100 Ethernet ports on an MM314 media module.
Step 6: Install the Coupled Bonding Conductor
The Coupled Bonding Conductor (CBC) provides mutual inductance coupling between the CBC and the 
telephone cables that are exposed to lightning. The conductor can be a 10 AWG (4 mm
2
) wire tie wrapped 
to the exposed cables, a metal cable shield around the exposed cables, or six spare pairs from the exposed 
cable. In a high-rise building, connect the CBC to an approved building ground on each floor.
Before you begin, be sure the telephone lines are cross-connected to the appropriate media module(s).
To install the CBC
1
Connect one end of the conductor to a telephone cable building entrance protector ground that is 
connected to an approved ground.
2
Route the rest of the conductor next to the exposed telephone cables being protected until they 
reach the cross-connect nearest to the telephone system.
3
Terminate the other end to the single-point ground block provided for the telephone system.
NOTE:
Position the non-exposed telephone cables at least 12 in. (30.5 cm) away from exposed 
telephone cables whenever possible.