Avaya G350 User Manual

Page of 60
Technical specifications
G350 Media Gateway specifications
Installation of the G350 Media Gateway
55
December 2003
A
Technical specifications
This appendix provides technical specifications for the G350 and for compatible power cords. 
G350 Media Gateway specifications
The table of technical specifications provides detailed information on the physical dimensions and 
tolerances of the G350 Media Gateway.
Power Cord Specifications
Following are specifications for power cords suitable for use with the G350:
For North America: The cordset must be UL Listed/CSA Certified, 16 AWG, 3-conductor (3rd wire 
ground), type SJT. One end is to be terminated to an IEC 60320, sheet C13 type connector rated 10A, 
250V. The other end is to be terminated to either a NEMA 5-15P attachment plug for nominal 125V 
applications or a NEMA 6-15P attachment plug for nominal 250V applications.
For Outside North America: The cord must be VDE Certified or Harmonized (HAR), rated 250V, 3-
conductor (3rd wire ground), 1.0 mm2 minimum conductor size. The cord is to be terminated at one end 
to a VDE Certified/CE Marked IEC 60320, sheet C13 type connector rated 10A, 250V and the other end 
to a 3-conductor grounding type attachment plug rated at a minimum of 10A, 250V and a configuration 
specific for the region/country in which it will be used. The attachment plug must bear the safety agency 
certifications mark(s) for the region/country of installation.
Table 2: G350 Media Gateway specifications
Description
Value
Height
5.25 in. (133.3 mm)
Width
19 in. (482.6 mm)
Depth
15.75 in. (400 mm)
Weight of empty chassis
9-10 kg 
Ambient working temperature
0-40
°
C
Operation altitude
up to 2000 m
Front Clearance
12 in. (30 cm)
Rear Clearance
18 in. (45 cm)
Humidity
20-60% relative humidity