Paradyne 1900 User Manual

Page of 160
1900-A2-GN20-00
BitStorm 1900 Installation and Maintenance Guide
3-103
3. BitStorm 1900 Maintenance
This chapter contains guidelines and checklists for the maintenance of 
the BitStorm 1900 system.
Maintenance Guidelines
The following factors can cause service problems in an EtherLoop sys-
tem installation:
Poor wiring conditions
Incomplete cable connections
Improper BitStorm 1900 equipment installation
Improper data network equipment configuration
Equipment failure
The following sections briefly describe each of these potential problem 
causes.
Wiring Conditions
In general, EtherLoop systems can function well on standard, twisted 
pair phone lines (Category 3 or better). However, in older facilities, 
extremely poor wiring conditions may exist that can adversely impact 
EtherLoop performance, Also, RJ-11 wall jack connectors can become 
corroded, which may not impact voice service other than generating 
some static on the line, but can interfere with EtherLoop data service.