NEC NDA-30115-001 User Manual

Page of 116
NDA-30115  Revision 1.0
Page 19
Property Management System - Communication Interface
Message Descriptions
Chapter 3
Message Descriptions
There are several message groups:
Data Link Maintenance Messages
Maid Status
Message Waiting Lamp Control
Restriction Control
Check In/Check Out (Model 60)
Check In/Check Out (Model 90)
Wake Up/Group Announcement
Room Move/Swap/Copy (Model 60)
Room Data Change
Extension Report
Room Recovery (Model 60)
Room Recovery (Model 90)
Direct Data Entry (Model 90)
Extension Connection
Each message group will be described briefly in the following sections.
The NEAX equates rooms with extensions, one extension per room. The exception 
to this is the suite room feature. When this feature is activated in the NEAX, a 
primary extension represents a group of extensions in one or more rooms. For a 
suite room, the PMS should reference only the primary extension in its messages 
to the NEAX. All associated extensions will inherit the attributes of the primary 
extension and should effectively be ignored by the PMS.
Data Link Maintenance
These are the messages used by the PMS and NEAX to maintain communication.
The PMS must regularly send Nop Test messages with an interval of no more than 
60 seconds, and no less than 500 milliseconds, between each message. The NEAX 
will immediately respond with either a Nop Test Normal Answer, under normal 
conditions, or a Nop Test Recover Answer, if a database recovery for the NEAX is 
needed.
Nop Test Normal Answer -- Whenever a Nop Test message is sent by the PMS, 
the NEAX responds by sending this message, unless the NEAX has just 
finished an error recovery.
Nop Test Recover Answer -- If the NEAX has been performing an error 
recovery, this message is sent in response to the Nop Test in the place of the Nop 
Test Normal Answer message.