NEC NDA-30115-001 User Manual

Page of 116
Page 32
NDA-30115  Revision 1.0
Message Formats
Property Management System - Communication Interface
Note 3:
In the case of messages that are almost identical, the FC will be marked with 
“**”. Also, differing FTC values will be marked with “*”. The final message is 
then constructed by simply inserting the desired FC value (and, if necessary, the 
desired FTC value).
All messages in this section have been previously defined in NEAX2400 IMS Hotel 
System PMS Interface Specification
 (except for one Maid Status message, which is 
so noted). The versions supported are Model 60 and Model 90; Model 120 
messages are not supported. Any message that is intended to work with only one 
version is so designated; any message that is intended to work with both has no 
special designation.
The Feature Codes used are as follows:
70 -- Data Link Maintenance
11, 12, 51, 52 -- Maid Status
13, 53 -- Message Waiting Lamp Control
15 -- Restriction Control
16 -- Check-In/Out (Model 60)
56 -- Check-In/Out (Model 90)
19 -- Wake Up/Group Announcement
20 -- Room Move/Swap/Copy (Model 60)
21, 61 -- Room Data Change
17 -- Extension Report
17 -- Room Recovery (Model 60)
57 -- Room Recovery (Model 90)
59 -- Direct Data Entry (Model 90)
62 -- Extension Connection
Data Link Maintenance
These messages are used by the NEAX and the PMS to maintain the data link 
between them. The messages are as follows:
70-0 -- Nop Test Normal Answer (Sent by NEAX)
70-2 -- Nop Test Recover Answer (Sent by NEAX)
70-3 -- Recovery Start Report (Sent by PMS)
70-4 -- Recovery End Report (Sent by PMS)
70-5 -- Data Link Release Request (Sent by PMS and NEAX)
70-6 -- Data Link Release Confirmation. (Sent by PMS and NEAX)
70-8 -- Extension Number Request (Sent by PMS)
70-F -- Nop Test (Sent by PMS)