NEC NDA-30115-001 User Manual

Page of 116
Page 34
NDA-30115  Revision 1.0
Message Formats
Property Management System - Communication Interface
51-7 -- Guest Room 7 (Model 90) 
Note:
This message was not previously defined in NEAX2400 IMS Hotel System PMS 
Interface Specification.
51-8 -- Negative Answer (Model 90)
51-9 -- Positive Answer (Model 90)
52-1 -- Administration 1 (Model 90)
52-2 -- Administration 2 (Model 90)
52-3 -- Administration 3 (Model 90)
52-4 -- Administration 4 (Model 90)
All messages designated “Model 90” are used only by the Model 90 version. The 
other messages are used by either the Model 60 or the Model 90 version.
Cleaning
Figure 4-3   Cleaning (General)
Message fields are:
FTC -- Feature Codes that use this message format are: 11 and 12.
FC -- Function Codes that use this message format are: (FTC-FC)
11-1 -- Cleaning Start (Guest)
11-2 -- Cleaning End (Guest)
11-3 -- Inspection End (Guest)
11-4 -- Out of Order (Guest)
12-1 -- Cleaning Start (Administration)
12-2 -- Cleaning End (Administration)
12-3 -- Inspection End (Administration)
Extension -- Extension number. If the extension number is less than six digits, 
left justify the number and fill the remaining bytes with space (20H) characters.
Maid -- Identification number of the maid. If the maid identification number is 
less than six digits, left justify the number and fill the remaining bytes with 
space (20H) characters.
‘1’
*
‘1’
‘7’
** Extension
Maid
** Multiple Function Codes use this message. See below.
* Multiple Feature Codes use this message. See below.
0
1
2
3
4
6
8
9
15
21
22
STX
SA
UA
EI
FTC
MSC
FC
6
6
02H ‘1’
‘!’
‘L’
03H xx