NEC NDA-30115-001 User Manual

Page of 116
Page 36
NDA-30115  Revision 1.0
Message Formats
Property Management System - Communication Interface
Room Answer
Figure 4-5   Room Answer (General)
Message fields are:
FC -- Function Codes that use this message format are: (FTC-FN)
51-8 -- Negative Answer (Model 90)
51-9 -- Positive Answer (Model 90)
Extension -- Extension number.   If the extension number is less than six digits, 
left justify the number and fill the remaining bytes with space (20H) characters.
LEN -- Line Equipment Number.
Request -- Room Status Change Request. The possible values are:
0 -- Room Status is not to be changed.
1 -- Room Status is to be changed.
Room Status -- Room status. This flag is used in conjunction with the cleaning 
status flag to determine the status of the room.
Cleaning Status -- Cleaning status. The possible combinations with room status 
are listed below:
LEN
** Multiple Function Codes use this message. See below.
Request
Room
Status
Cleaning
Status
‘5’
‘1’ ‘2’
‘0’
** Extension
0
1
2
3
4
6
8
9
15
21
STX
SA
UA
EI
FTC
MSC
FC
6
6
1
02H ‘1’
‘!’
‘L’
03H xx
ETX BCC
22
23
24
25
1
1
2
2
0
0
0
0
0
1
0
1
2
4
Stay, Departure Day
Stay, Departure Day, Cleaning in progress
Out (Checked Out)
Out, Cleaning in progress
Out, Cleaning ended
Out of Order (Cannot sell)
Room
0
1
1
Clean
3
0
1
Status of the Room
Vacant (Ready to sell)
Stay (Occupied)
Stay, Cleaning in progress
1
1
2
3
Stay, Cleaning ended
Stay, Inspected