NEC NDA-24233 User Manual
NDA-24233 Issue 2
Page 3-15
VisuaLink 128/384 Engineering Guide
Console Command List
SMTC
Sets Audio or Audio/Video Mute Setting
2-13
RMTC
Checking Audio or Audio/VideoOutput Mute Setting
2-14
Description:
Sets whether the audio or audio and video outgoing is muted or unmuted
at the start of communication when the VisuaLink automatically answers
or manual answered calls.
at the start of communication when the VisuaLink automatically answers
or manual answered calls.
Command Format:
SMTC p1
p1:
A:
Audio is set to be Muted (Default)
AV:
Video/Audio is set to be Muted
Response:
Normal Response: OK
Description:
Reads what is to be MUTED at the start of communication.
Command Format:
RMTC
Response:
Normal Response: p1 OK
p1:
A
:
Audio is set to be Muted
AV
:
Video/Audio is set to be Muted