Console Command List
SMTC
Sets Audio or Audio/Video Mute Setting
2-13
RMTC
Checking Audio or Audio/VideoOutput Mute Setting
2-14
Description:
Sets whether the audio or audio and video outgoing is muted or unmuted 
at the start of communication when the VisuaLink automatically answers 
or manual answered calls.
Command Format:
SMTC p1 
p1:  
A:
Audio is set to be Muted (Default)
AV:
Video/Audio is set to be Muted
Response:
Normal Response:  OK
Description:
Reads what is to be MUTED at the start of communication.
Command Format:
RMTC
Response:
Normal Response:  p1 OK
p1:
A
Audio is set to be Muted
AV