NEC NDA-24233 User Manual

Page of 124
Page 3-18
NDA-24233 Issue 2
Console Command List
VisuaLink 128/384 Engineering Guide
SLSP
Setting Transmission Line Speed
3-5
RLSP
Checking Transmission Line Speed Setting
3-6
Note:
The response will always be a 64 kbps increment.  It is recommended that the RNET command be used 
combined with RLSP.
Description:
Sets transmission speed.
Command Format:
SLSP  p1 
p1:
B
: 56/64 
kbps
2B
: 2x56/2x64 
kbps
3B
:
168/192 kbps
4B
:
224/256 kbps
5B
:
280/320 kbps
6B
:
336/384 kbps
Response:
Normal Response:  OK
Error Response:  
Note:  If VL128, setting 3B to 6B results in error.
Description:
Checks the current transmission speed setting.
Command Format:
RSLP
Response:
Normal Response:  p1 OK
p1: 64
: 56/64 
kbps
2x64 : 2x56/2x64 
kbps
192
:
168/192 kbps
256
:
224/256 kbps
320
:
280/320 kbps
384
:
336/384 kbps
Error Response: