Nortel Networks NN43001-318 User Manual

Page of 108
Packet data transmission
101
acknowledgment that the receiving ISDN BRI terminal is ready, the
call-originating ISDN BRI terminal can begin transmitting packet
data.
2
Verify that the transmitted data has been received successfully
by checking the transmitted information for accuracy. Read the
information on the screen or print it on the local printer.
3
Release the connection.
—End—
Repeat this test on other ISDN BRI packet data terminals as needed.
Procedure 38
Perform a D-channel packet data transmission test using an external packet
handler
Step
Action
1
From an ISDN BRI D-channel packet data terminal, dial another
ISDN BRI packet data terminal and establish an active call
connection.
After the call-originating ISDN BRI terminal receives an
acknowledgment that the receiving ISDN BRI terminal is ready,
the call-originating ISDN BRI terminal can begin transmitting
packet data.
2
Verify that the transmitted data has been received successfully
by checking the transmitted information for accuracy. Read the
information on the screen or print it on the local printer.
3
Release the connection.
—End—
Procedure 39
Perform a D-channel Switched Virtual Circuit packet data transmission test
using an MPH
Step
Action
1
From an ISDN BRI D-channel packet data terminal, dial another local
ISDN BRI packet data terminal or a remote packet data terminal
(depending on how you have configured your MPH application).
Establish an active call connection.
Nortel Communication Server 1000
ISDN Basic Rate Interface Installation and Commissioning
NN43001-318
01.02
Standard
Release 5.0
20 June 2007
Copyright © 2003-2007, Nortel Networks
.