Testing ISDN BRI functions
2
After the call-originating ISDN BRI terminal receives an
acknowledgment that the receiving ISDN BRI terminal is ready, the
call-originating ISDN BRI terminal can begin transmitting packet
data.
3
Verify that the transmitted data has been received successfully
by checking the transmitted information for accuracy. Read the
information on the screen or print it on the local printer.
4
Perform this test between two ISDN BRI terminals on the same MPH
for local transmission and between a system ISDN BRI terminal
and a remote ISDN BRI terminal over the Packet Switched Data
Network (PSDN).
5
Release the connection.
—End—
Procedure 40
Perform a B-channel Switched Virtual Circuit packet data transmission test
using an MPH
Step
Action
1
From an ISDN BRI B-channel packet data terminal, dial the Network
Terminal Numbers (NTNs) as configured in LD 27. Establish an
active call connection.
2
After the call-originating ISDN BRI terminal receives an
acknowledgment that the receiving ISDN BRI terminal is ready, the
call originating ISDN BRI terminal can begin transmitting packet data.
3
Verify that the transmitted data has been received successfully
by checking the transmitted information for accuracy. Read the
information on the screen or print it on the local printer.
4
Perform this test between two ISDN BRI terminals on the same MPH
for local transmission and between a system ISDN BRI terminal and
a remote ISDN BRI terminal over the packet data network.
5
Release the connection.
—End—