Provisioning
Detailed calculation: Method 2
This method is used when incoming Digitone trunks are included in the 
system. This method uses the same assumptions as Method 1, with the DTR 
holding time assumed to be 2.5 seconds for a DID call. Follow the procedure 
below for detailed calculation Method 2.
1
Calculate intra-office and outgoing Digitone calls as shown in step 1 of 
Method 1:
DID calls = 100 x Digitone station traffic (in CCS)
           call holding time in seconds
2
Calculate total DTR traffic:
DTR traffic = 1.3 x [(6.2 x intra) + (14.1 x outgoing)] + (2.5 x DID calls)
100
3
See Table 30, “Digitone receiver (DTR) requirements — Poisson 0.1 
percent blocking,” on page 126 a
nd use the answer from step 2 to 
determine the number of DTRs required.
Calculating total system load
Total the line, trunk, console and DTR load for each customer to get the total 
load figure for each customer, two-year and five-year intervals. Enter this 
figure into “Worksheet B: Total load” on page 137.
Calculating number of loops required
Loop provisioning is not required with Option 11C since each card is 
automatically assigned to its own loop. By default, the system is non-
blocking.
Each cabinet can house up to 10 Intelligent Peripheral Equipment (IPE) cards.
Each Option 11C Mini chassis can house up to 4 IPE cards.