Calculating number of IPE cards required
Using information from “Worksheet A: Growth forecast” on page 135, enter 
the number of Meridian Digital Telephone TNs, Analog (500/2500 type) 
TNs, and trunk TNs required at cutover, two-year, and five-year intervals (for 
all customers) in “Worksheet C: System cabinet / Main chassis requirements” 
on page 138.
Divide each entry by the number of TN assignments for each card, round up 
to the next higher figure, and total the number of cards required.
IPE card slot assignments with IP Expansion
If you are using IP Expansion cabinets, then trunk and line cards may be 
distributed throughout each of the system cabinets in such a way as to allow 
for survival operation. The intent is for a cabinet equipped with both trunk 
and line cards in survival mode to still handle calls.
IPE card slot assignments without IP Expansion
If you are not using IP Expansion cabinets, then trunk and line cards should 
be placed in the system cabinets in such a way as to allow for future 
expansion. Line cards are placed in the left hand slots of the cabinets. If the 
system is using the default numbering plan and consecutive DN numbering is 
desired, the line cards should be placed one after another leaving no blank 
slots in between. Trunk cards are placed in the right hand slots of the cabinets.
Plan the card slot assignments so that the trunk and line card growth is 
towards the middle. For example Figure 6 on page 105 shows the slot 
assignment plan for systems equipped with two expansion cabinets.
IPE card slot assignments on the Option 11C Mini Main Chassis
Digital trunks cards must be placed in the main chassis. Slot 4 must contain 
the 48 port DLC. Figure 9 on page 107 shows the typical card slot assignment 
for the Option 11C Mini Main.
Note: Slot 4 is keyed to prevent accidental insertion of cards other than 
the 48 port DLC.