Nortel Networks Option 11C User Manual

Page of 546
M5317 BRI Terminal
Page 339 of 544
Electromagnetic emissions
The M5317T telephones are specified to comply with the limits for Class A, 
Subpart J of the Federal Communications Commission (FCC), Part 15 and 
Class B, CSA C108.8, CISPR22 Class B (AS 3548).
Atmospheric pollution
Each M5317T telephone is designed to withstand normal atmospheric 
conditions throughout its life and during shipment. It meets exposure tests for 
salt, mist, atmospheric dust, sulfur dioxide and hydrogen sulfide as defined in 
IEC document 50.
Terminal powering
Line engineering
The telephones will operate to their full potential through twisted pair wiring. 
Powering alternatives
The telephones are powered through the RJ connectors and the line cord. 
They may be powered from one of the following sources:
PS1, phantom power conducted over the “T” line card or the NT1
PS2, auxiliary DC power conducted over a third pair in the line cord 
(may be provided independently of the NT1 or line card)
Local DC power conducted over a third pair from a power pack 
(connected by means of an RJ-45 plug connector with the DC power 
terminated on its pin 7 (PS2-) and pin 8 (PS2+) inserted into one of the 
wall-mounted RJ sockets.
A dip switch (switch A), accessible through a small hatch in the base of the 
telephone housing, must be set to select between the phantom powering (PS1) 
or powering provided by a third pair (PS2 or local AC).