M5317 BRI Terminal
Page 341 of 544
North America
Minimum AC voltage at outlet: 97 V rms
Maximum AC voltage at outlet: 132 V rms
Average maximum AC current required: 100 mA
AC supply frequency: 60 Hz
Minimum transformer output voltage: 24 V DC
Maximum transformer output voltage: 34 V DC
Features
Display
The 155 x 15 mm (6 x 0.6 in.) alphanumeric LCD assembly has a display 
capacity of two 40-character lines. In NI-1 and Meridian 1 modes, the first 
line usually displays date and time (during the idle state only), incoming call 
identification, connection information, feature icons, user prompts, and 
messages.
Figure 50
Display icons (enlarged view)
The second line displays the context-dependent softkey functions 
(8 characters per key, including spaces) in accordance with the state of the 
terminal, whenever applicable. If there are more than five choices available, 
a more... softkey is shown. The softkey labels always give the currently valid 
commands and features. Pressing that softkey displays additional labels 
available for the accessed telephony state.
If MFT mode is used, both lines of the LCD may be used for call information.
Displays are defined by the switch software, and may vary between software 
loads. In BCS34, the idle display is blank, and at other times call progress 
information is displayed on both lines.