Provisioning
This method is used for each trunk group in the system, with the exception of
small special services trunk groups (such as tie, WATS, and FX trunks).
Normally, the customer will tolerate a lesser grade of service on these trunk
groups. Table 20 lists the estimated usage on special services trunks.
small special services trunk groups (such as tie, WATS, and FX trunks).
Normally, the customer will tolerate a lesser grade of service on these trunk
groups. Table 20 lists the estimated usage on special services trunks.
Default method
Studies conducted estimate that the average line CCS/T is never greater than
5.5 in 90 percent of all businesses. If attempts to calculate the CCS/T using
the comparative method or the manual calculation are not successful, the
default of 5.5 line CCS/T can be used.
5.5 in 90 percent of all businesses. If attempts to calculate the CCS/T using
the comparative method or the manual calculation are not successful, the
default of 5.5 line CCS/T can be used.
The network line usage is determined by multiplying the number of lines by
5.5 CCS/T. The total is then multiplied by two to incorporate the trunk CCS/
T. However, when this method is used, the intra CCS/T is added twice to the
equation, and the result could be over provisioning if the intra CCS/T is high.
5.5 CCS/T. The total is then multiplied by two to incorporate the trunk CCS/
T. However, when this method is used, the intra CCS/T is added twice to the
equation, and the result could be over provisioning if the intra CCS/T is high.
Another difficulty experienced with this method is the inability to forecast
individual trunk groups. The trunk and intra CCS/T are forecast as a sum
group total. Examples of the default method and the manual calculation
method are shown in Table 21 for comparison.
individual trunk groups. The trunk and intra CCS/T are forecast as a sum
group total. Examples of the default method and the manual calculation
method are shown in Table 21 for comparison.
Table 20
Estimated load per trunk
Estimated load per trunk
Trunk type
CCS
Tie
30
Foreign exchange
30
Out WATS
30
In WATS
30
Paging
10
Dial dictation
10
Individual bus lines
20