Nortel Networks 4050 User Manual

Page of 922
Chapter 12 Configuring SNMP 627
Nortel Secure Network Access Switch 4050 User Guide
 
The Notification Target menu includes the following options:
Configuring SNMP events using the CLI
The Nortel SNAS 4050 supports three kinds of SNMP monitors, as defined in the 
DISMAN-EVENT-MIB:
boolean — checks the value of a monitored object identifier (OID) against a 
specific value, and triggers an event if the result matches a specified 
operation.
threshold — compares a monitored OID against a range of values, and 
triggers events if the comparison determines that the OID value is rising too 
quickly, falling too quickly, or falls outside certain boundaries
existence — checks the condition of a monitored OID to determine if it is 
present, absent, or changed, and triggers an event if the result matches the 
specified condition
To configure monitors and events defined in the DISMAN-EVENT-MIB, use the 
following command:
/cfg/sys/adm/snmp/event
The event menu displays.
/cfg/sys/adm/snmp/target <target ID>
followed by:
ip <IPaddr>
Specifies the IP address to which trap messages are 
sent.
IPaddr
 is the IP address of the SNMP manager.
port <port>
Specifies the TCP port used by the SNMP manager. 
The default is port 162.
version v1|v2c|v3
Specifies the SNMP version used by the SNMP 
manager. Valid options are:
v1
 — SNMP version 1
v2c
 — SNMP version 2c
v3
 — SNMP version 3
The default is 
v2c
.
del
Removes the current SNMP manager from the Nortel 
SNAS 4050 configuration.