Finisar FTLF1217P2XTL User Manual

Page of 13
FTLF1217P2xTL Pluggable SFP Product Specification – September 2008 
 
 
 
© Finisar Corporation September 13, 2008 Rev. B   
Page 7 
 
VIII.   Digital Diagnostic Functions 
 
Finisar FTLF1217P2xTL SFP transceivers support the 2-wire serial communication 
protocol as defined in the SFP MSA
1
. It is very closely related to the E
2
PROM defined in 
the GBIC standard, with the same electrical specifications. 
 
The standard SFP serial ID provides access to identification information that describes 
the transceiver’s capabilities, standard interfaces, manufacturer, and other information. 
 
Additionally, Finisar SFP transceivers provide a unique enhanced digital diagnostic 
monitoring interface, which allows real-time access to device operating parameters such 
as transceiver temperature, bias current, transmitted optical power, received optical 
power and transceiver supply voltage.  It also defines a sophisticated system of alarm and 
warning flags, which alerts end-users when particular operating parameters are outside of 
a factory set normal range. 
 
The SFP MSA defines a 256-byte memory map in E
2
PROM that is accessible over a  
2-wire serial interface at the 8 bit address 1010000X (A0h). The digital diagnostic 
monitoring interface makes use of the 8 bit address 1010001X (A2h), so the originally 
defined serial ID memory map remains unchanged. The interface is identical to, and is 
thus fully backward compatible with both the GBIC Specification and the SFP Multi 
Source Agreement. The complete interface is described in Finisar Application Note AN-
2030: “Digital Diagnostics Monitoring Interface for SFP Optical Transceivers”. 
 
The operating and diagnostics information is monitored and reported by a Digital 
Diagnostics Transceiver Controller (DDTC) inside the transceiver, which is accessed 
through a 2-wire serial interface. When the serial protocol is activated, the serial clock 
signal (SCL, Mod Def 1) is generated by the host.  The positive edge clocks data into the 
SFP transceiver into those segments of the E
2
PROM that are not write-protected.  The 
negative edge clocks data from the SFP transceiver.  The serial data signal (SDA, Mod 
Def 2) is bi-directional for serial data transfer. The host uses SDA in conjunction with 
SCL to mark the start and end of serial protocol activation. The memories are organized 
as a series of 8-bit data words that can be addressed individually or sequentially. 
 
For more information, please see the SFP MSA documentation
1,7
 or Finisar Application 
Note AN-2030. 
 
Please note that evaluation board FDB-1018 is available with Finisar ModDEMO 
software that allows simple to use communication over the 2-wire serial interface.