IX.   Digital Diagnostic Specifications 
 
FTLF1217P2xTL transceivers have internally calibrated digital diagnostics. 
 
Parameter Symbol 
Min 
Typ 
Max 
Units 
Ref. 
Accuracy 
 
 
 
 
 
 
Internally measured transceiver 
temperature 
DD
Temperature
 
 
± 3 
ºC  
Internally measured transceiver 
supply voltage 
DD
Voltage
 
 
± 100 
mV  
Measured TX bias current 
DD
Bias
 
 
± 10 
Measured TX output power 
DD
Tx-Power
 
 
± 3
 
dB  
Measured RX received average 
optical power 
DD
Rx-Power
 
 
± 3 
dB  
Dynamic Range for Rated Accuracy 
Internally measured transceiver 
temperature 
DD
Temperature
-40   85 ºC 
 
Internally measured transceiver 
supply voltage 
DD
Voltage
3.0   3.6 V 
 
Measured TX bias current 
DD
Bias
0  70 
mA 
 
Measured TX output power 
DD
Tx-Power
-22   -13 
dBm 
 
Measured RX received average 
optical power 
DD
Rx-Power
-33   -12 
dBm 
 
Max Reporting Range 
 
 
 
 
 
 
Internally measured transceiver 
temperature 
DD
Temperature
-40   125 
ºC 
 
Internally measured transceiver 
supply voltage 
DD
Voltage
2.8   4.0 V 
 
Measured TX bias current 
DD
Bias
0  80 
mA 
 
Measured TX output power 
DD
Tx-Power
-24   -11 
dBm 
 
Measured RX received average 
optical power 
DD
Rx-Power
-35   -10 
dBm 
 
 
Notes: 
1.  Accuracy of Measured Tx Bias Current is 10% of the actual Bias Current from the driver to the LED.