3.4 C-Soft 
Setup 
Note 
This example shows a basic setup for C-Soft. Please refer to the User manual for other 
Vega IP based consoles if necessary
3.4.1 
Setup IP Multicast List 
 
Figure 4 Setup IP Multicast List – iDen® Radio in Phone Mode operation 
Figure 4 shows an example of setting two lines in Phone mode. In this example, the Line Type is 
selected as Phone mode. The Line Name is arbitrary and called Line 31 and Line 32 in this case. 
The Rx port numbers need to be unique; typically they are just the next number in a standard 
assignment sequence. The Base Radio IP address will be the IP address of the IP-223 that is 
connected to the NI223
plus. 
3.4.2 
Set Global Parameters 
 
Figure 5 Setup Global Parameters - Phone Ring Multicast and Port 
Figure 5 shows the Phone Ring Multicast and Port number setting. This value will be the same as 
that shown in Figure 1.