Lantronix 10 User Manual

Page of 139
Configure 
UDS-10 User Guide 
3-15 
3.6 Channel 1 Configuration (Serial Port Parameters)  
Using this option, define how the serial port will respond to network and serial 
communications
Baudrate (9600)
I/F Mode (4C)
Flow (00)
Port No (10001)
ConnectMode (C0)
Remote IP Address : (000).(000).(000).(000)
Remote Port (00000)
DisConnMode (00)
FlushMode
(00)
DisConnTime (00:00) :
SendChar 1
(00)
SendChar 2
(00)
3.6.1 Baudrate  
The unit and attached serial device, such as a modem, must agree on a speed or baud rate to 
use for the serial connection. Valid baud rates are 300, 600, 1200, 2400, 4800, 9600 (default), 
19200, 38400, 57600, and 115200 bits per second. 
3.6.2 I/F (Interface) Mode  
The Interface (I/F) Mode is a bit-coded byte that you enter in hexadecimal notation.  
Note: See Table 35 - Binary to Hexadecimal Conversion Table.  
Table 6 - Interface Mode Options 
I/F Mode Option  
 7   6   5   4   3   2   1   0  
RS-232C 
(1)
 
 
 
 
 
 
 
0  
0  
RS-422/485 
(1) 
 
 
 
 
 
 
 
0  
1  
RS-485 2-wire 
(1)
 
 
 
 
 
 
 
1  
1  
Bit 
 
    1 
 
 
  
Bit 
 
    1 
 
 
  
No Parity  
 
 
0  
 
 
 
 
Even 
Parity 
 
  1 1 
 
    
Odd 
Parity 
 
  0 1 
 
    
1 Stop bit  
0  
1  
 
 
 
 
 
 
2 Stop bit  
1  
1  
 
 
 
 
 
 
(1) The UDS-10 requires you to choose the correct setting in the IF mode.