Lantronix 10 User Manual
Configure
UDS-10 User Guide
3-15
3.6 Channel 1 Configuration (Serial Port Parameters)
Using this option, define how the serial port will respond to network and serial
communications
communications
.
Baudrate (9600)
I/F Mode (4C)
Flow (00)
Port No (10001)
ConnectMode (C0)
Remote IP Address : (000).(000).(000).(000)
Remote Port (00000)
DisConnMode (00)
FlushMode
I/F Mode (4C)
Flow (00)
Port No (10001)
ConnectMode (C0)
Remote IP Address : (000).(000).(000).(000)
Remote Port (00000)
DisConnMode (00)
FlushMode
(00)
DisConnTime (00:00) :
SendChar 1
SendChar 1
(00)
SendChar 2
(00)
3.6.1 Baudrate
The unit and attached serial device, such as a modem, must agree on a speed or baud rate to
use for the serial connection. Valid baud rates are 300, 600, 1200, 2400, 4800, 9600 (default),
19200, 38400, 57600, and 115200 bits per second.
use for the serial connection. Valid baud rates are 300, 600, 1200, 2400, 4800, 9600 (default),
19200, 38400, 57600, and 115200 bits per second.
3.6.2 I/F (Interface) Mode
The Interface (I/F) Mode is a bit-coded byte that you enter in hexadecimal notation.
Note: See Table 35 - Binary to Hexadecimal Conversion Table.
Note: See Table 35 - Binary to Hexadecimal Conversion Table.
Table 6 - Interface Mode Options
I/F Mode Option
7 6 5 4 3 2 1 0
RS-232C
(1)
0
0
RS-422/485
(1)
0
1
RS-485 2-wire
(1)
1
1
7
Bit
1
0
8
Bit
1
1
No Parity
0
0
Even
Parity
1 1
Odd
Parity
0 1
1 Stop bit
0
1
2 Stop bit
1
1
(1) The UDS-10 requires you to choose the correct setting in the IF mode.