Configure 
UDS-10 User Guide 
3-17 
3.6.3 Flow  
Flow control sets the local handshake method for stopping serial input/output.  
Table 8 - Flow Control Options 
Flow Control Option  
Hex  
No flow control  
00  
XON/XOFF flow control  
01  
Hardware handshake with RTS/CTS lines 
02  
XON/XOFF pass characters to host  
05  
3.6.4 Port Number  
The setting represents the source port number in TCP connections, and is the number used to 
identify the channel for remote initiating connections. Default setting for Port 1 is 10001. 
Range: 0-65535 except for the following reserved port numbers: 
  
Port Numbers  
Reserved for  
1 – 1024 
Reserved (well known ports) 
9999  
Telnet setup  
14000-14009  
Reserved 
30718 Reserved 
(77FEh) 
10000-10999 
Recommended ports, should be used for DeviceComm 
Manager (COM1-COM256) or direct socket connections 
 
The port number functions as the TCP/UDP source port number for outgoing packets. 
Packets sent to the unit with this port number are received to this channel. The port number 
selected is the Incoming TCP/UDP port and Outgoing TCP/UDP source port. Port 0 is used 
when you want the outgoing source port to change with each connection.