Delta Electronics DVPCOPM-SL User Manual

Page of 32
CANopen Communication Module DVPCOPM-SL 
DVP-PLC Application Manual 
20 
z Program 
explanations: 
1.  The first 3 rows of the program set up the communication format between DVP-SA and IFD9503, 
which is 115,200bps, 7E1-ASCII; communication port is COM2. 
2.  When M0 = On, send the input status of X20 ~ X28 on DVP-08ST to D256, and send the data in b0 ~ 
b15 of D0 to M10 ~ M25. 
3.  When D0 = 1, M10 will be On, and Y0 on DVP-SA MPU will output. 
Sending SDO, NMT and Reading Emergency by Ladder Diagram 
5.1 The 
Principle 
See the chart below for sending SDO by WPL program: 
P
O R
T 2
P O
R T 1
DVPCOPM
DVP28SV
RUN
STOP
IFD9503
VFD-B
DVP28SV
DVPCOPM-SL
SDO response message
(COPM -> PLC)
SDO request message
(PLC -> COPM)
A
D
C
B
SDO request message from master
SDO response message from slave
 
A: DVP-SV sends out request message to DVPCOPM-SL (master). 
B: DVPCOPM-SL (master) sends out request message to the target equipment. 
C: The target equipment processes the request message and sends the response message to 
DVPCOPM-SL. 
D: DVP-SV receives SDO, NMT and Emergency data. 
5.2 
Structure of SDO Request Message 
You can edit SDO, NMT and Emergency in “request message editing area”. Take the first DVPCOPM-SL 
master placed on the left hand side of DVP-SV for example. See the table below for the corresponding releation 
between “request message editing area” and “response message editing area” and the devices in PLC.